Sy-I081V_Leep Surgery System Diathermy Machine High Frequency Leep Electrosurgical Unit for Gynecology

Product Details
Customization: Available
Type: Diathermy Machine
Application: Orthopedic, Neurosurgery
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (22)
  • Sy-I081V_Leep Surgery System Diathermy Machine High Frequency Leep Electrosurgical Unit for Gynecology
  • Sy-I081V_Leep Surgery System Diathermy Machine High Frequency Leep Electrosurgical Unit for Gynecology
  • Sy-I081V_Leep Surgery System Diathermy Machine High Frequency Leep Electrosurgical Unit for Gynecology
  • Sy-I081V_Leep Surgery System Diathermy Machine High Frequency Leep Electrosurgical Unit for Gynecology
  • Sy-I081V_Leep Surgery System Diathermy Machine High Frequency Leep Electrosurgical Unit for Gynecology
  • Sy-I081V_Leep Surgery System Diathermy Machine High Frequency Leep Electrosurgical Unit for Gynecology
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Packaging & Shipping
  • FAQ
  • Company Profile
Overview

Basic Info.

Model NO.
SY-I081V_Leep
Feature
Reusable
Certification
CE
Group
Human
Place of Origin
Guangdong, China
Instrument Classification
Class II
Brand Name
Sunnymed
Model Number
Sy-I081V_Leep
Product Name
Electrosurgical Generator
Pure Cut
200W
Blend Cut
150W
Soft Coag
100W
Strong Coag
80W
Bipolar Coag
50W
Working Frequency
360kHz~460 kHz
Safety Standard
GB15979-2002
Properties
The Basis of Surgical Instruments Sizetoptional
Selling Unit
Single Item
Single Package Size
55X55X40 Cm
Transport Package
Carton
Specification
Single package size: 55X55X40 cm Single gross weig
Trademark
Sunnymed
Origin
Guangdong, China

Product Description

Product Description

 

Sy-I081V_Leep Surgery System Diathermy Machine High Frequency Leep Electrosurgical Unit for GynecologySy-I081V_Leep Surgery System Diathermy Machine High Frequency Leep Electrosurgical Unit for Gynecology
Scope of Application: It is suitable for various gynecological surgeries on cutting, coagulation, condylomata acuminate, columnar ectopy, and LEEP. It is also used with laparoscope, hysteroscope, etc.
Functional Features:
1. Cutting: that is pure cutting, the effect is fine cutting, tissue surface is fresh and no scab;
2. Blend: The effect is to provide good coagulation while cutting. It is suitable for superficial coagulation of tissue in surgery and can be used with endoscopy.
3. Coag 1: It can be called soft electrocoagulation or point coagulation. It is suitable for deeper coagulation of tissue in surgery and can be used with endoscopy. Because a smaller area of action can reduce adhesion between electrodes and tissue, it is better for the rehabilitation of patients.
4. Coag 2: It can be called strong electrocoagulation or surface coagulation. It has faster coagulation and a larger area of action.
5. Bipolar Coag: It can be called rapid bipolar electrocoagulation. It can achieve the effect of coagulation at the moment of start-up and reduce the rate of misoperation during surgery.
Advantages of High-Frequency Electrotome:
1. Independent output port of endoscope and intelligent conversion key, which can enter endoscopic mode automatically after start-up.
2. Microcomputer control system, power-off protection, and memory function of keeping last usage data after restart.
3. Automatic adjustment on output power. It can be adjusted automatically according to the change of density of tissue. Stable output power to keep the minimum wastage.
4. Automatic conversion on monopolar and bipolar.
5. Automatic monitoring of on-off, automatic detection, and error prompts in work.
6. The monitoring circuit system on contact quality of neutral electrodes can test and evaluate the safety and effectiveness of the contact area between the electrode plate and skin. The system can cut off output automatically and give an alarm, in case of finds that the contact area is at a dangerous level. It can test and use
 
 
Advantages of LEEP:
1. The use of Loop Electrosurgical Excision Procedure (LEEP) for gynecologic uterine lesions has improved the accuracy, controllability, and security of surgeries.
2. It can be applied to the treatment of various gynecological diseases (including cutting, coagulation, condylomata acuminate, columnar ectopy, and LEEP, it can be also used with laparoscope, hysteroscope), so it reduces the procedure and the cost of surgeries.
3. Electrodes with various shapes are suitable for cervical conization and vulvar surgery, without carbonization and any influence on pathological tissue.
4. Spherical electrodes can be used for hemostasis. They do not burn blood vessels, do not damage nearby tissues, and make patients recover faster after surgeries.
5. Electrodes of needle shape can be used for fine cutting. 6. Electrodes with different sizes have different hemostatic effects.
Mono cut
Cutting: 200W (load 500)
Mono Coag
Soft Coag: 100W (load 500)
 
Blend: 150W (load 500)
 
Strong Coag: 80W (load 500)
Bipolar
Bipolar Coag: 50W (load 200)
Ambient temperature range: 10ºC~40ºC;
Relative humidity range: 30%~75%;
Atmospheric pressure range: 700hpa~1060hpa;
Power supply: 220V (±22V), 50Hz (±1Hz);
Working frequency: 360kHz~460 kHz;
Type of equipment: CF;
The power consumption of the whole device is less than 1000VA. (Cutting function: 200W)
Detailed Photos

 

Sy-I081V_Leep Surgery System Diathermy Machine High Frequency Leep Electrosurgical Unit for GynecologySy-I081V_Leep Surgery System Diathermy Machine High Frequency Leep Electrosurgical Unit for GynecologySy-I081V_Leep Surgery System Diathermy Machine High Frequency Leep Electrosurgical Unit for GynecologySy-I081V_Leep Surgery System Diathermy Machine High Frequency Leep Electrosurgical Unit for GynecologySy-I081V_Leep Surgery System Diathermy Machine High Frequency Leep Electrosurgical Unit for Gynecology
Packaging & Shipping

Sy-I081V_Leep Surgery System Diathermy Machine High Frequency Leep Electrosurgical Unit for Gynecology

FAQ
1. How to buy?
A. Contact our sale directly!
B. Place the order online.
Sy-I081V_Leep Surgery System Diathermy Machine High Frequency Leep Electrosurgical Unit for Gynecology
2. How to pay?
A. Trade assurance
B. Credit Card
C. Paypal 
D.T/T(Bank Transfer)
E. Western union
F. L/C

Return policy


3. How long to wait for the order?A. Ready stock within 24 hours
B. OEM need 2-7 working days
C.
Safety delivery:special one-to-one inspection service before arranging the delivery
Sy-I081V_Leep Surgery System Diathermy Machine High Frequency Leep Electrosurgical Unit for Gynecology
4. How to use our product?
A. Video tutorial: including installation, operation, repairing and maintenance
B.
Real Time Online Video Call at your convenience: Pre-sales and after-sales online video training


5. Warranty and after-sales serviceA.12-60 months
B. After-sales service: Reply within
8 hours
Company Profile

We are based in Guangdong, China, starting from 2014. Products are sold to South America, Southeast Asia, North America, and Africa, ect. .
Sy-I081V_Leep Surgery System Diathermy Machine High Frequency Leep Electrosurgical Unit for Gynecology

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More