Customization: | Available |
---|---|
Classification: | Biochemical Apparatus |
Type: | Urine Analyzer |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Specification:
Principle: Electrical resistance for counting,hemiglobincyanide method and SFT
method for hemoglobin
Parameters: 3-part differential of WBC;20parameters + 3 color histograms(WBC
/RBC/PLT)
Sample Consumption: Venous Mode:9.6μL Capillary Mode:9.6μL Pre-diluted
Mode:20μL
Operation Mode: Windows operation system with keyboard&mouse input
Throughput: 35 samples/hour
Storage: 12,000 sample results inclusive of the histograms
QC mode: L-J,X,X-B,SD,CV,QC histogram
Cross Contamination Ratio: WBC/RBC/HGB<0.5%,PLT<1%
Performance: Parameter Repeatability(CV%) Linear Range
WBC≤2.0% 0.00-99.9x109/L RBC≤1.9% 0.00-9.99x1012/L
HGB≤1.9% 0-300g/L MCV≤0.4% 40-150fL
PLT≤4.0% 0-999x109/L
Display: 8.4"LCD,resolution:640x480
Reference Value: Baby,Kid,Woman,Man,Normal and Customization
Interface: 2xUSB,1xparallel(for external printer),1xVGA(for external monitor)
2xPS/2,2xRS-232(for network)
Printer: Built-in thermal recorder,optional external printer,eight report formats
Principle
|
Electrical resistance for counting, hemoglobincyanide method and SFT method for hemoglobin
|
|
Parameters
|
3-part differential of WBC, 20 parameters+3 color histograms (WBC/RBC/PLT). 20 parameters: WBC, LYM%, MID%, NEUT%, LYM#, MID#,
NEUT#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, P-LCR |
|
Sample Volume
|
Venous Mode: 9.8uL, Capillary Mode: 9.8uL, Pre-diluted: 20uL
|
|
Working Mode
|
Counting passages detection+independent HGB measurement system, 24 hours with auto standby
|
|
Operation Mode
|
Touch screen operation, keyboard and mouse operation
|
|
Throughput
|
60 samples per hour
|
|
Data Storage
|
Up to 15,000 results inclusive of the histograms
|
|
QC mode
|
L-J, X, X-B, SD, CV, QC histograms
|
|
Calibration Mode
|
Relatively independent manual calibration and auto calibration in 3 detecting modes
|
|
Cross Contamination Ratio
|
WBC, RBC, HGB<0.5%, PLT<1%
|
|
Performance
|
Parameter Repeat-ability Linear Range
WBC≤2.5% 0.00-99.9×108 /L
RBC≤2.0% 0.00-9.99×1012/L
HGB≤1.5% 0-300.0 g/L
MCV≤0.4% 40-150fL
PLT≤5.0%(100-500) 0-999×109/L |
|
Display
|
8.4 inch LCD, resolution 800×600
|
|
Reference value
|
Baby, Kid, women, man, normal and customization
|
|
Interface
|
2×USB, 1×parallel (for external printer), 1×VGA (for external monitor), RS232(for network)
|
|
Printout
|
Built-in thermal recorder, optional external printer, 8 report format
|
|
Working Environment
|
Temperature: 15-35ºC, Humidity:10-90%
|
|
Power Requirement
|
AC100-240V 50/60Hz
|
Carton Size:
58*48*60 cm
Carton G/W:
27KG / unit