• Sy-B037 Lab Equipment Medical Products Electrophoresis Apparatus
  • Sy-B037 Lab Equipment Medical Products Electrophoresis Apparatus
  • Sy-B037 Lab Equipment Medical Products Electrophoresis Apparatus
  • Sy-B037 Lab Equipment Medical Products Electrophoresis Apparatus
  • Sy-B037 Lab Equipment Medical Products Electrophoresis Apparatus
  • Sy-B037 Lab Equipment Medical Products Electrophoresis Apparatus

Sy-B037 Lab Equipment Medical Products Electrophoresis Apparatus

Classification: Biochemical Apparatus
Type: Biochemistry Analyzer
Certification: CE
Name: Electrophoresis Analyzer
Voltage Shift: ≤0.2%
Power Supply: 220V±10% 50Hz
Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
SY-B037
Current Range
0~400mA
Voltage Range
0~600V
Transport Package
Carton Box
Specification
CE, ISO
Trademark
Sunnymed
Origin
Guangdong
Production Capacity
500 Set/ Month

Product Description


SY-B037 Lab Equipment Electrophoresis Apparatus
 

Technical data

 

Voltage range 0~600V
Current range 0~400mA
Voltage shift ≤0.2%
Current shift ≤0.2%
Working mode   Constant current or constant voltage
Output format   in four groups synchronously
Power supply 220V±10%  50Hz
Fuse BGXP-5  5A

Sy-B037 Lab Equipment Medical Products Electrophoresis Apparatus

 
 
 
 
Operating instructions

 
1) Connect the output ends to the gel box. The red end is positive electrode (anode) and the black one is 
negative electrode (cathode).
 
2) Revolve the knob of "Adjust" anticlockwise until it stops.
 
3) Press the button of "Power" to switch on power supply and lighten the digital panel. 
 
4) Choose a constant mode
 
constant voltage mode
 
   Press the button of "constant T" to turn on the indicator light of "constant T".
 
   Now the electrophoresis apparatus is working on constant voltage mode.
 
constant current mode
 
   Press the button of "constant A" to turn on the indicator light of "constant A".
 
   Now the electrophoresis apparatus is working on constant current mode.
 
5) Revolve the knob of "Adjust" clockwise gently until it reaches a certain value of voltage or current.
 
Cautions
 
1) DO NOT connect the electrophoresis apparatus to the gel box with the power on. Also, DO NOT pull out 
the output cables that connecting the apparatus to the gel box with the power on. Always Connect the 
electrophoresis apparatus to the gel box BEFORE turning the power supply ON.
 
2) Assume that you want to set the voltage value to "150V" at the constant voltage mode. If the current value 
becomes extremely high or even overflows the rated value (400mA) before you could adjust the voltage value 
to 150V, do examine whether the electrophoresis apparatus is well connected to the gel box or the 
electrophoresis buffers is accurately prepared. 
 
3) When more than one gel boxes are working together, choose the constant voltage mode to reduce the 
interactions between boxes.
 
4) PULL the power cables OUT OF the power supply when changing the fuse. Specification of the new fuse 
should accord with that indicated in "Technical data"
 
 
Accessories
 
1) British power cable  1
 
2) Output cables    2
 
3) Operation Manual   1
 
4) Test report  1
 
5) Certificate of soundness 1
 
6) Defects liability card  1
 
7) "BGXP-5, 5A" fuse    2
Sy-B037 Lab Equipment Medical Products Electrophoresis Apparatus
Sy-B037 Lab Equipment Medical Products Electrophoresis Apparatus
Sy-B037 Lab Equipment Medical Products Electrophoresis Apparatus
Sy-B037 Lab Equipment Medical Products Electrophoresis Apparatus
Sy-B037 Lab Equipment Medical Products Electrophoresis Apparatus
Sy-B037 Lab Equipment Medical Products Electrophoresis Apparatus

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now